Enter your email address to receive your free PDF download. Please note that by doing so you agree to be added to our monthly email newsletter distribution list. Yes, sign me up for the Cureus monthly newsletter. You can unsubscribe anytime. New here? Sign up. Sign in to Cureus sign in using LinkedIn sign in
Autonomous RCM-less endoscope control: integrating force-based pivoting with deep learning visual servoing – Scientific Reports
- Article
- Open access
- Published:
Scientific Reports (2026) Cite this article
We are providing an unedited version of this manuscript to give early access to its findings. Before final publication, the manuscript will undergo further editing. Please note there may be errors present which affect the content, and all legal disclaimers apply.
Subjects
Abstract
Robotic endoscope holders improve visual stability, yet enforcing a fixed remote center of motion (RCM) often induces lateral interaction forces due to fulcrum drift. This study proposes an autonomous guidance framework combining deep learning–based visual servoing with force-based pivoting to track surgical instruments while minimizing interaction forces, without a fixed geometric RCM. To test this, a UR3e manipulator with an integrated force/torque sensor controlled a laparoscope in a pelvitrainer. Instruments were localized using a fine-tuned YOLOv11n on 3,695 annotated frames. The detected tools’ centroids drove a hysteresis-based visual servoing law with jerk-limited planning, while an admittance-based controller generated angular motion from measured forces. Performance was assessed in continuous tracking and step-response tasks, comparing fixed-RCM with the proposed pivoting approach. The localization model achieved 0.91–0.93 precision, 0.83–0.90 mAP, and 28 FPS on a CPU. Visual servoing re-centered targets in 98.8% of transitions (median recovery: 2.60 s). Force-based pivoting significantly outperformed fixed-RCM control, reducing median interaction forces from 2.35 to 0.19 N. Integrating CNN-driven servoing with force-based pivoting enables autonomous guidance that preserves visual stability while substantially reducing interaction forces. By eliminating fixed RCM assumptions, this framework offers a safer, more adaptive alternative for robotic camera assistance.
Funding
This project has been funded by the Spanish Ministry of Science, Innovation and Universities through PID2022-138206OB-C33.
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material. You do not have permission under this licence to share adapted material derived from this article or parts of it. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc-nd/4.0/.
Reprints and permissions
About this article
Cite this article
Fontúrbel, C., Cisnal, A., Benavides-Cobos, D. et al. Autonomous RCM-less endoscope control: integrating force-based pivoting with deep learning visual servoing. Sci Rep (2026). https://doi.org/10.1038/s41598-026-54550-9
Download citation
-
Received:
-
Accepted:
-
Published:
-
DOI: https://doi.org/10.1038/s41598-026-54550-9
Keywords
Supplementary Material 2