Deep Learning Enables Automatic Thalamic Ultrasound Volumetry in Premature

Deep learning algorithms can accurately segment the thalamus in cranial three-dimensional ultrasound scans of premature infants, yielding segmentation overlap and relative volume difference values close to 0.88 and 9 percent. In a new feasibility study, researchers applied supervised deep learning networks to cranial ultrasound to quantify a neonatal brain structure other than the lateral ventricles for the first time. The findings demonstrate that automated volumetric analysis can achieve results comparable to magnetic resonance imaging while utilizing accessible ultrasound technology.

Brain abnormalities that cause neurodevelopmental disorders in premature infants involve a combination of destructive lesions and developmental abnormalities that restrict normal brain growth. While quantitative brain imaging using magnetic resonance imaging has established predictive value for infant neurodevelopment in clinical research settings, automated magnetic resonance imaging segmentation methods cannot be routinely deployed in everyday neonatal care. Consequently, quantitative assessment of brain structures has remained largely unavailable for at-risk infants during the critical neonatal period.

To evaluate whether three-dimensional ultrasound could provide a practical clinical alternative, investigators examined 15 premature infants born at less than 33 weeks of gestation. Clinicians conducted freehand ultrasound scanning to record dynamic sequences of two-dimensional images. Using a dedicated reconstruction algorithm, the team reconstructed 16 cranial three-dimensional ultrasound volumes from these dynamic scans, capturing the anatomical structures across coronal, axial, and sagittal imaging planes prior to algorithmic segmentation.

To establish ground truth data for training and evaluating neural networks, researchers generated an annotated database through manual segmentation. Reference contours were created on coronal sections following the three-dimensional reconstruction process for patients in the database. The researchers partitioned the resulting 16 reconstructed volumes into eight volumes for model training, three volumes for validation, and five volumes for final model testing.

The investigation evaluated three distinct supervised deep learning architectures for the automated segmentation task. These included two convolutional neural networks, designated U-Net and V-Net, alongside E-SegNet, a U-shaped segmentation network incorporating a Vision Transformer framework. The evaluation relied on two primary quantitative metrics: the Dice similarity coefficient to measure the overlap rate between automatic and manual segmentations, and the relative volume difference to evaluate volumetric accuracy.

Assessment of measurement reliability showed low baseline variability across observers and reconstruction stages. Intra-observer variability produced a Dice similarity coefficient of 0.91 alongside a relative volume difference of 1.58 percent, while inter-observer variability demonstrated a Dice similarity coefficient of 0.89 and a relative volume difference of 7.58 percent. Furthermore, the variability associated with the volume reconstruction procedure itself remained low, achieving a Dice similarity coefficient of 0.86 and a relative volume difference of 4.82 percent.

Across the test dataset, all three evaluated neural networks delivered segmentation performance with metrics close to a Dice similarity coefficient of 0.88 and a relative volume difference of 9 percent. The authors concluded that these deep learning algorithms successfully perform thalamic segmentation in cranial three-dimensional ultrasound, offering promising prospects for neurodevelopmental prediction and broader access to quantitative neonatal brain imaging.

To evaluate model performance, the researchers examined axial surface variation across predictions in a representative test case. This qualitative comparison analyzed a worst-case scenario for the baseline U-Net architecture alongside the three-dimensional-aware V-Net and the Vision Transformer-based E-SegNet.

Published as a basic science article in Pediatric Research, the study demonstrates that ultrasound volumetry achieves results comparable to magnetic resonance imaging for neonatal thalamic quantification. The authors noted that automated cranial ultrasound can enable all at-risk premature infants to access quantitative brain imaging during the neonatal period. Finally, because of sensitivity reasons, the underlying study data are not openly available, but remain accessible from the corresponding author upon reasonable request.

Subject of Research: Deep learning-based automatic thalamic segmentation using cranial 3D ultrasound in premature infants

Article Title: Quantitative thalami volumetry in premature infants using cranial 3D ultrasound and automatic segmentation with deep learning approaches

Article References: Quetin, P., Nguyen, K.-L., Martin, M., Davila, E., Estermann, F., Grinand, M., Delachartre, P., & Boyer, C. (2026). Quantitative thalami volumetry in premature infants using cranial 3D ultrasound and automatic segmentation with deep learning approaches. Pediatric Research. https://doi.org/10.1038/s41390-026-05631-y

Image Credits: AI Generated

DOI: 10.1038/s41390-026-05631-y

Keywords: cranial 3D ultrasound, thalamus segmentation, premature infants, deep learning, convolutional neural networks, U-Net, V-Net, E-SegNet, Vision Transformer, thalamic volumetry, gestational age, Dice similarity coefficient, relative volume difference, pediatric neuroimaging, axial surface variation, neonatal brain abnormalities, manual segmentation

colind88